NABL ISO/IEC 17025:2017 accredited scope FSSAI-notified food laboratory
Andheri East, Mumbai +91 97110 84272 Submit a sample
Home/Services/Water & Environmental Testing

Water & Environmental Testing

Water and environmental testing against IS 10500, IS 14543 and MPCB consent conditions.

Overview

Scope of water and environmental testing

Praman holds accredited scope for potable and packaged drinking water, process and boiler water, sewage and industrial effluent, ambient air, stack emissions, noise, soil and sludge. Reports are issued in the formats the Maharashtra Pollution Control Board and municipal authorities expect.

Our field team carries out the sampling itself where a result has legal or consent consequences, because a perfect analysis of a badly drawn sample is a perfectly useless number.

Who sends us environmental work

  • Manufacturing plants under MPCB consent
  • Housing societies and townships
  • Hotels, hospitals and malls
  • Packaged drinking water plants
  • Construction and infrastructure projects
  • Municipal and civic bodies
  • Pharmaceutical and chemical units
  • Data centres and IT parks
Scope

What we test

Drinking water

  • IS 10500 acceptable and permissible limits
  • IS 14543 packaged drinking water, full schedule
  • Heavy metals by ICP-MS
  • Pesticide residues in water
  • Total and faecal coliforms, E. coli
  • Residual chlorine, hardness, TDS, turbidity

Process & utility water

  • Boiler feed and cooling tower water
  • RO permeate and softener performance
  • Purified water for pharmaceutical use
  • Legionella screening
  • Silica, phosphate and alkalinity
  • Microbial count and biofilm indicators

Effluent & wastewater

  • BOD, COD, TSS, oil and grease
  • Heavy metals against consent limits
  • Ammoniacal and total nitrogen, phosphates
  • Phenolics, cyanides and sulphides
  • STP and ETP inlet/outlet performance
  • Consent-condition compliance reporting

Ambient & workplace air

  • PM2.5 and PM10 gravimetric
  • SO2, NOx, CO and ozone
  • Volatile organic compounds
  • Ambient noise and workplace noise dosimetry
  • Illumination surveys
  • Indoor air quality assessments

Stack emissions

  • Particulate matter, isokinetic sampling
  • SO2, NOx, CO from combustion sources
  • Hydrocarbons and acid mists
  • Stack velocity, temperature and flow
  • DG set emission testing
  • Periodic compliance monitoring contracts

Soil, sludge & waste

  • Soil fertility and nutrient profile
  • Heavy metals in soil and sludge
  • TCLP leachate characterisation
  • Hazardous waste classification
  • Compost and manure quality
  • Contaminated land assessment support
Methods

Representative parameters and limits

A sample of the accredited scope. The full annexure, with every method reference and measurement uncertainty, is issued with your quotation.

ParameterMethodTypical LOQTAT
Full IS 10500 panelIS 3025 series / APHAParameter dependent7 days
Heavy metals in waterAPHA 3125 / ICP-MS0.0005 mg/L3 days
BOD (3 days at 27°C)IS 3025 Part 441 mg/L5 days
CODAPHA 5220 C5 mg/L2 days
Total coliforms & E. coliIS 1622 / APHA 92211 MPN/100 mL4 days
PM2.5, ambient (24 h)CPCB gravimetric method5 µg/m³5 days
Stack particulate matterIS 11255 Part 1, isokinetic5 mg/Nm³6 days
Oil & greaseAPHA 5520 B2 mg/L3 days
Questions

Frequently asked questions

Our environmental scope is NABL accredited and the laboratory is recognised for environmental monitoring in Maharashtra. Reports are issued with the consent conditions reproduced alongside measured values, in the format the board expects with returns. We will share a specimen report before you commission the work.

For consent-linked, legal or tender work, we sample, using our own trained team, chain-of-custody seals and preserved containers issued by us. For routine internal monitoring you can submit your own samples, provided they arrive in our containers within the holding time for the parameters requested.

Microbiological samples must reach us within six hours at 4°C. Most chemical parameters allow 24 to 48 hours with correct preservation; BOD and residual chlorine are far shorter. We issue a holding-time sheet with the sampling kit and we will reject a sample that arrives outside it rather than report a number we do not trust.

Yes. Multi-site contracts include a fixed sampling calendar, our own field team, consolidated monthly reporting and a trend dashboard that flags parameters drifting towards a consent limit before they cross it.

Both, routinely, pools against IS 3328 style parameters including residual chlorine, pH and microbiology, and recycled STP water against the end-use quality your application requires, whether that is flushing, gardening or cooling tower make-up.

Consent renewal or a board notice?

We run express environmental panels for consent renewals, show-cause responses and tender submissions. Tell us the deadline and we will tell you honestly whether we can meet it.

Call the lab Get a quote